1:2.2 Safety notes
Clearances provided at the sides and rear of the appliance for air entry must be kept free of obstruction. For
further explanation please refer to section 4:6 of this installation manual.
Your
Boulter Buderus
Boiler should be connected to an electric supply complying with the Electrical Wiring
Regulations (BS 7671): as well as an oil supply complying with the BS 5410 Pt.1; and an appropriate flue
system.
z ALWAYS SWITCH OFF THE ELECTRICAL SUPPLY before removing any of the covers for cleaning,
z If any part of the Boiler or its flue is modifies, then the guarantee/warranty will be invalidated.
1:3 INSTALLATION &COMMISSIONING
A
fte
r
your Boulter Buderus Boiler has been installed it MUST be commissioned by a competent O.F.T.E.C.
registered engineer, or by one of our registered service engineers. Commissioning involves testing the Boiler
to ensure that it is working correctly, and also setting the Burner correctly to ensure the most efficient
operation and use of fuel. If the Boiler has not been commissioned, it may not be operating at the maximum
efficiency possible for your heating system, and may also invalidate the guarantee
Page 3
1:4 BOILER CONTROL PANEL
Boiler Control Panel
1.Boiler Control Thermostat Switch/Mains On Switch.
2.Boiler Overheat/Limit Thermostat reset button.
1:5 OPERATING INSTRUCTIONS
1:5.1 BOILER CONTROL THERMOSTAT
The Boiler Control Thermostat is also the ON/OFF switch for the Boiler. To switch the Boiler off, turn the
Thermostat to the 'OFF' position.
The Boiler Control Thermostat controls the water temperature within the Boiler. The recommended Control
Thermostat settings are as follows:
WINTER HEATING & HOT WATER 4
SUMMER HOT WATER ONLY 2
The Boiler Control Thermostat automatically switches the Burner ON and OFF to maintain the selected
temperature. The Burner is lit by an automatic ignition system and therefore there is no pilot flame.
The Boiler should not be operated below 60ºC (Summer position) as this will cause corrosion which will
reduce the life of the Boiler.