BOILER CONTROL THERMOSTAT
1:5.2 BOILER OVERHEAT/LIMIT THERMOSTAT
The boiler is fitted with a safety overheat/limit thermostat. This will interrupt the power supply to the Boiler and
shut it down completely in the unlikely event of overheating.
Wait for the Boiler to cool, and then reset the thermostat by pressing the limit thermostat reset button located
on the Control Panel.
If this problem still persists turn off the Boiler and consult your installer.
1:5.3 LOCKOUT INDICATOR
In the unlikely event of a burner malfunction, it will automatically shutdown, and the red lockout indicator on
the Burner Control Box will be lit.
To reset the Burner, wait for a period of at least 45 seconds. Press the lockout reset button located on the
front of the Burner If the Burner immediately goes to lockout again, wait three minutes and then repeat the
procedure, once more only, by pressing the reset button again.
If this problem still persists, turn off the Boiler and consult your engineer.